Page 5 - larwqcb20110404sos
P. 5

A  .   Placerita Canyon Site Order No. 89-1 6
                 Monitoring & Reporting Program No. CI-6857







                                               ANALYTICAL                        MINIMUM FREQUENCY
                        CONSTITUENT                                 UNITS
                                                  METHOD                               OF ANALYSIS
                '
                  Benzene                        EPA 8260B                              Semi-Annual
                   1,l -Dichloroethane           EPA 8260B           ~.lgk              Semi-Annual
                   1,2-Dichloroetl~ane           EPA 8260B           pg/L               Semi-Annual
                   1,l -Dichloroethene           EPA 8260B           P~/L               Semi-Annual
                  Tetrachloroethene              EPA 8260B           ~gk                Semi-Annual
                  l,l, 1 -Trichloroethane        EPA 8260B           Y~L                Semi-Annual
                  Toluene                        EPA 8260B           mg1L               Semi-Annual
                  Trichloroethene                EPA 8260B           mg/L               Semi-Annual
                  trans-l,2-Dichloroethene       EPA 8260B           mg/L               Semi-Annual
                  cis- l,2-Dichloroethene        EPA 8260B           mg/L               Semi-Annual
                  Xylenes                        EPA 8260B           mgk                Semi-Annual
                  Total Flow                        In situ         gallday             semi-~nnual'

                 (in gallons) since the last monitoring event by the number of days since the last monitoring event.

             \
                 111.   INFLUENT MONITORING PROGRAM               '
                        The Discharger shall conduct influent monitoring at the site.  A representative sample shall be
                        collected from' the established Main (Area 11) Treatment System influent sampling station.  The
                        Main (Area 11) Treatment System influent shall be monitored for the duration' of its operation in
                        accordance with the following influent monitoring program:
           1
                                                                                            \
                                               ANALYTICAL                        MINIMUM FREQUENCY
             \         CONSTITUENT                                  UNITS
                                                 METHOD                               OF ANALYSIS        .
                  Benzene                        EPA 8260B           P~/L               Seini-Annual
                  1,l -Dichloroethane            EPA 8260B        I  P~IL               Semi-Annual
                  1 ,2-Dichloroethane            EPA 8260B        I                     Semi-Annual
                  1,l-Dichloroethene             EPA 8260B           ~gk                Semi-Annual
           I
                  Tetrachloroethene              EPA 8260B           clgk               Semi-Annual
       ,   .  ;   1,l, 1 -Trichloroethane        EPA 8260B           P~L                Semi-Annual
                '
                  ~oluene                        EPA 8260B        '  in&                Semi-Annual
                  Trichloroethene                EPA 8260B        I  mg/L               Semi-Annual  '
                  trans-l,2-Dichloroethene       EPA 8260B          mg/L                Semi-Annual
                  cis- 1 ,ZDichloroethene        EPA 8260B          rngk                Semi-Annual
                  Xylenes                        EPA 8260B          mgk                 Serni-Annual
           ,      Total Flow                        In situ       '  gallday            semi-Annual'
       .    ~
   1   2   3   4   5   6   7